Magnetic Flow Meters - Electromagnetic Flow Meters - Flow Technology & Burkert
FTI and Burkert lines of electromagnetic flow meters are cost-effective to measure all electrically conductive liquids (> 5 µS/cm) in process applications. The new generation of meters incorporates improvements to the magnetic distribution elements which allows more accurate operation throughout all flow regimes, allowing up to a 1000:1 turndown.
Specification & Documentation

Industrial process application Mag Meter
| | Capacity -Water | | | Max Pressure | Fluid Temp | | |
| Model | lpm | gpm | Accuracy | Repeatability | Bar | Psig | C | F | Construction | Connection |
 EL 2200 FTI General Purpose | 5.22 to 71086 | 1.38 to 18779 | 0.2% OR | 0.1% | Dependent on flange rating | -40 to 180 | -40 to 356 | Housing: Acrylic painted carbon steel, optional stainless steel
Electrode: Hastelloy C22 / Platinum / Titanium / Tantalum
Liner: PTFE / Ebonite | Flanged |
|
 8055 Burkert General Purpose | 0.24 to 4666 | 0.06 to 1232 | 0.2% OR | 0.1% | 63 | 928 | -20 to 130 | -4 to 266 | Housing: Carbon steel Painted
Electrode: 316L/ Hastelloy C / Titanium / Tantalium / Platinum-rhodium
Liner: PP/ PTFE
Gasket: FKM/ EPDM/ PTFE | Wafer & Flanged |
|
Sanitary applications Mag Meter
| | Capacity -Water | | | Max Pressure | Fluid Temp | | |
| Model | lpm | gpm | Accuracy | Repeatability | Bar | Psig | C | F | Construction | Connection |
 EL 2400 FTI Sanitary | 6 to 4997 | 1.6 to 1320 | 0.2% OR | 0.1% | 16 | 232 | -40 to 140 | -40 to 284 | Housing and Fitting: 304 stainless steel
Electrode: 316L / Hastelloy C22 / Titanium
Liner: PTFE | Tri-Clamp & DIN 11851 |
|
 8056 Burkert Sanitary | 0.003 to 4666 | 0.0009 to 1232 | 0.2% OR | 0.1% | 16 | 232 | -20 to 130 | -4 to 266 | Housing: 304 stainless steel
Electrode: 316L SS
Liner: PTFE
Gasket: FKM/ EPDM/ | DIN11851, Clamp ISO2852 or Clamp BS4825 |
|
Low flow & small line Mag Meter
| | Capacity -Water | | | Max Pressure | Fluid Temp | | |
| Model | lpm | gpm | Accuracy | Repeatability | Bar | Psig | C | F | Construction | Connection |
 EL-500 FTI Low flow Measurement | 0.083 to 166.6 | 0.02 to 44 | 0.2% OR | 0.1% | 16 | 232 | -20 to 160 | -4 to 320 | Housing: 304 stainless steel
Electrode: 316L SS (standard) / Hastelloy C22 / Titanium
Liner: PTFE | NPT, TriClamp, DIN 11851, UNI 338 |
|
 8051 Burkert Low flow Measurement | 0.003 to 208 | 0.0008 to 55 | 0.2% OR | 0.1% | 40 | 580 | -20 to 130 | -4 to 266 | Housing: 304 stainless steel
Electrode: 316L SS (standard) / Hastelloy C/ Titanium/ Tantalum/ Platinum-rhodium
Liner: PTFE/ FKM/ EPDM/ FFKM | Threaded |
|
Insertion Mag Meter
| | Measuring Range | | | Max Pressure | Fluid Temp | | |
| Model | m/s | Accuracy | Repeatability | Bar | Psig | C | F | Wetted parts material | Connection |
 8041 - 8045 Burkert Insertion Mag Meter | 0.2 to 10 | 0.2% OR | 0.25% OR | 16 | 232 | -15 to 150 | -3 to 302 | Sensor armature: PVDF/316L
Electrode: 316L/HastelloyC22
Gasket: FKM | Insertion |
|