Flow Meters & Flow Controllers

FTI


Magnetic Flow Meters - Electromagnetic Flow Meters - Flow Technology

FTI's line of electromagnetic flow meters are cost-effective to measure all electrically conductive liquids (> 5 µS/cm) in process applications. The new generation of meters incorporates improvements to the magnetic distribution elements which allows more accurate operation throughout all flow regimes, allowing up to a 1000:1 turndown.


Specification & Documentation

Industrial process application Mag Meter

  Capacity -Water     Max Pressure Fluid Temp    
Model lpm gpm Accuracy Repeatability Bar Psig C F Construction Connection

EL 2200 FTI

EL 2200 FTI
General Purpose
5.22
to
71086
1.38
to
18779
0.2% OR 0.1% Dependent on flange rating -40
to
180
-40
to
356
Housing: Acrylic painted carbon steel, optional stainless steel

Electrode: Hastelloy C22 / Platinum / Titanium / Tantalum

Liner: PTFE / Ebonite
Flanged

8055 Burkert

8055 Burkert
General Purpose
0.24
to
4666
0.06
to
1232
0.2% OR 0.1% 63 928 -20
to
130
-4
to
266
Housing: Carbon steel Painted

Electrode: 316L/ Hastelloy C / Titanium / Tantalium / Platinum-rhodium

Liner: PP/ PTFE

Gasket: FKM/ EPDM/ PTFE
Wafer & Flanged

Sanitary applications Mag Meter

  Capacity -Water     Max Pressure Fluid Temp    
Model lpm gpm Accuracy Repeatability Bar Psig C F Construction Connection

EL 2400 FTI

EL 2400 FTI
Sanitary
6
to
4997
1.6
to
1320
0.2% OR 0.1% 16 232 -40
to
140
-40
to
284
Housing and Fitting: 304 stainless steel

Electrode: 316L / Hastelloy C22 / Titanium

Liner: PTFE
Tri-Clamp & DIN 11851

8056 Burkert

8056 Burkert
Sanitary
0.003
to
4666
0.0009
to
1232
0.2% OR 0.1% 16 232 -20
to
130
-4
to
266
Housing: 304 stainless steel

Electrode: 316L SS

Liner: PTFE

Gasket: FKM/ EPDM/
DIN11851, Clamp ISO2852 or Clamp BS4825

Low flow & small line Mag Meter

  Capacity -Water     Max Pressure Fluid Temp    
Model lpm gpm Accuracy Repeatability Bar Psig C F Construction Connection

EL-500 FTI

EL-500 FTI
Low flow Measurement
0.083
to
166.6
0.02
to
44
0.2% OR 0.1% 16 232 -20
to
160
-4
to
320
Housing: 304 stainless steel

Electrode: 316L SS (standard) / Hastelloy C22 / Titanium

Liner: PTFE
NPT, TriClamp, DIN 11851, UNI 338

8051 Burkert

8051 Burkert
Low flow Measurement
0.003
to
208
0.0008
to
55
0.2% OR 0.1% 40 580 -20
to
130
-4
to
266
Housing: 304 stainless steel

Electrode: 316L SS (standard) / Hastelloy C/ Titanium/ Tantalum/ Platinum-rhodium

Liner: PTFE/ FKM/ EPDM/ FFKM
Threaded

Insertion Mag Meter

  Measuring Range     Max Pressure Fluid Temp    
Model m/s Accuracy Repeatability Bar Psig C F Wetted parts material Connection

8041 - 8045 Burkert

8041 - 8045 Burkert
Insertion
Mag Meter
0.2
to
10
0.2% OR 0.25% OR 16 232 -15
to
150
-3
to
302
Sensor armature: PVDF/316L

Electrode: 316L/HastelloyC22

Gasket: FKM
Insertion