Flow Meters & Sensors

FTI

Hontzsch

Ultrasonic Flow Meters - Flow Technology & Hontzsch

FTI's & Hontzsch line of ultrasonic flow meters are an ideal solution for applications where it is preferable not to have an instrument exposed to the process fluid, were material compatibitly is an issue, for high pressure applications and for sanitary environments.

Ultrasonic flow meters are cost-effective to measure fluids which may be slightly charged with contaminants. Its non invasing design, using transmit time method, creates no pressure drop and requires no flow settling section at the inlet and/or outlet of the sensor.

Ultrasonic Flow meters Series


Specification & Documentation
  Range     Temp. range      
Model m/sec Accuracy Repeatability C F Output Construction Connection

SLF-500

SLF-500
Large Industrial piping
0
to
10
±2% OR ±0.2% -20
to
60
-4
to
140
1 analog, 3 open collector PVS, stainless steel and others Clamp-on on piping from 1 to 12 inches

SLF-200

SLF-200
1 to 6 inch line sizes
0
to
10
±1.5% OR ±0.2% -20
to
60
-4
to
140
1 analog, 1 open collector PVC, stainless steel, cast iron and others Clamp-on on piping from 1 to 6 inches

SLF-100

SLF-100
3/8, ½,
3/4 inch
PFA tubing clamp-on
0
to
10
±2% OR ±0.2% 10
to
60
50
to
140
1 analog, 1 open collector Glass fiber resin (Noril) Designed specifically for 3/8, 1/2 and 3/4 inch PFA tubing

Micro LF 100

Micro LF 100
3 or 6 mm PFA tubing
0.5
to
10
±2% OR ±0.2% 10
to
70
50
to
158
1 analog, 1 open collector Glass fiber resin (Noril) Sensors are supplied molded to a section of 3 or 6 mm PFA tubing which is inserted in the flow measurement line.

Ideal meter for semiconductor, low flow or corrosive applications.


  Capacity -Water   Pressure Fluid Temp      
Model lph gpm Accuracy Bar Psig C F Output Construction Connection

8081

8081
Low flow Measurement
3.6
to
12000
0.015
to
53
0.1% FS + 2% OR 15 230 5
to
90
41
to
194
Pulse, 4-20mA Brass Threaded